15
30 mm
Space for
connections
Clearance
Separator
Installation
Technical Information for the Installer
In order to install the hob into the kitchen fixture, a hole with the
dimensions shown in fig. 16 has to be made, bearing in mind the
following:
Within the unit, between the bottom of the hob and the upper
surface of a shelf there must be a clearance of at least 30mm.
It is absolutely essential that you place a separator between the
base of the hob and the built-in unit.
If the hob is installed over a built-in oven, there must be a
distance of at least 30mm between the two appliances. The oven
shall be provided with cooling fan. The two appliances should
be connected to the gas/electrical supply with independent
connections.
The hob must be kept no less than 100mm away from any side
wall (fig. 17).
The hob must be installed at least 50mm from the wall (fig. 16).
There must be a distance of at least 650mm between the hob
and any wall cupboard or extractor hood positioned immediately
above (see fig. 17).
Installation in Kitchen Cabinet with Door
It is recommended that a 30mm clearance be left between the
cooktop and the fixture surface (fig. 18).
Fig. 18
500 mm
650 mm
450 mm
490
50
(2)
270
300
510
52
(1)
Fig. 16
Fig. 17
(1): 52 mm from top of countertop
(2): at least 50 mm between the back
side of the cut-out and the back of
the countertop.
100 mm minimum between the side
of the cut-out and the side wall