Seitenansicht 12
ϱϮΘΤΗ Δϳέ΍ήΣ ΔΨπϤΑ ϞϤόΗ ϲΘϟ΍ ΓΰϬΟϷ΍ ϰϠϋΗ ΔϴδϜϋ Γ΍Ω΃ ϞϳΪόΘΑ ΢Ϥδ
έΎϴΘΧϻ΍ ϊϣ ϰηΎϤΘΗ ΔϘϳήτΑ ίΎϬΠϟ΍ ΎϫΪϟϮϳ ϲΘϟ΍ ΔϗΎτϟ΍"ΩέΎΒϟ΍ " ϭ΃"ϦΧΎδϟ΍."
Ϧϴ΋ΰΟ Ϧϣ ΓΪΣϮϟ΍ ϥϮϜΘΗ ΎϤϫ "ή
͋
ΨΒϤϟ΍ "ϭ"ϒ
˷
ΜϜϤϟ΍ " ϦϳάϠϟ΍ ϰϠϋ ΎϤϬΘϴΒΜΗ ϢΘϳ
ϘΜΑ ΓΩϭΰϣ ΓΪΣ΍ϭ ΩΎϨγ· ΔΣϮϟ ϰϠϋ ξϴϘϧ ϲϓήρ ϲϓ ϡΪΨΘδΗ ςϴΤϤϟ΍ ϰϠϋ
ΏϮ
ϰϠϋ ΔψϓΎΤϤϠϟ ΔΒγΎϨϣ ΔϴθΤΑϭ ˬϒϴϴϜΘϟ΍ ΔϘτϨϤϟ ϲΟέΎΨϟ΍ ϞϜϴϬϟ΍ ϰϠϋ ΖϴΒΜΘϟ΍
ΔΟέΪΑ ΔϳΎϤΤϟ΍ ΔΟέΩIP65.
ϮΤϧ
˱
ΎϬΠΘϣ ϥϮϜϴϓ ϒ
͋
ΜϜϤϟ΍ Ύϣ΃ ˬϲϠΧ΍Ϊϟ΍ ςϴΤϤϟ΍ ϮΤϧ
˱
ΎϬΠΘϣ ή
͋
ΨΒϤϟ΍ ϥϮϜϳ ˬϪϴϠϋ
ϲΟέΎΨϟ΍ ςϴΤϤϟ΍.
ϮϤΠϣ Ϧϣ ˯΍ϮϬϟ΍ ϒϴϴϜΗ ΓΰϬΟϷ Δϴδϴ΋ήϟ΍ ˯΍ΰΟϷ΍ ΔϋMAC-CWX/CRX
Ε΍Ϋ ΔϴϟΎΘϟ΍ Δϴ΋ΎΑήϬϜϟ΍ ϊτϘϟ΍ ϲϫ2GD ΕΎϘϴΛϮΗ ϰϠϋ
ΔϠλΎΣ ϲϫϭ
ˬΔϠϘΘδϣ.
ΎϨΘϋϮϤΠϣ ˬϞϳΪΑ ϖϠϐϣ ςϏΎοMCE˭
Ρϭ΍ήϤϟ΍ ΕΎϛήΤϣ ˭
ϲΒϟϮϟ ϒϠϤΑ ϡΎϤλΔϴδϜόϟ΍ Γ΍Ωϸϟ ΎϨΘϋϮϤΠϣ ˬMEV˭
˯ΎτϏ ϡϮϴϨϤϟϻ΍ ΔϜϴΒγ Ϧϣ ωϮϨμϣϱϮΘΤϳ ϰϠϋ ΔϘϠόΘϤϟ΍ ΓΰϬΟϷ΍
ϰϠϋϭ ϒ
˷
ϴϜϤϟ΍ ϞϴϐθΗ ϖτϨϤΑ ϲΘϟ΍ ΔϴϟΎΘϟ΍ Δϴ΋ΎΑήϬϜϟ΍ ήϴϏ ˯΍ΰΟϷ΍
ήρΎΨϤϟ΍ ϞϴϠΤΗ ΔϴϠϤόϟ ΖόπΧ :
Ρϭ΍ήϣ˭
ϊϣ ˬΔϔϨϋΰϣ ΔϳέΎτΑ ˬίΎϐϟ΍ϭ ˯΍ϮϬϟ΍ ΪϳήΒΘϟ Δϳέ΍ήΣ ΕϻΩΎΒϣ
ϡϮϴϨϤϟϻ΍ Ϧϣ ϒϧΎϋίϭ ΔϴγΎΤϧ ΐϴΑΎϧ΍ ˭
ΔϨϴϤΛ Ϛ΋ΎΒδΑ ϡϮΤϠϤϟ΍ αΎΤϨϟ΍ Ϧϣ ΔϋϮϨμϣ ΪϳήΒΗ Γέ΍Ω
. Γέ΍Ϊϟ΍
ϰϠϋ ϱϮΘΤΗ :΢ϴϔμΗ ίΎϬΟϒϴϔΠΗ ΢ηήϣ ˬλ ˬ ΕΎϣΎϤ Ϧϣ
Γέ΍ήΤϟ΍ϭ ςϐπϟ΍ ΔΒϗ΍ήϣ ΓΰϬΟ΍ ˬήϔλϻ΍ αΎΤϨϟ΍˭
ΕΎϋϮϤΠϣ Ϧϣ ˯΍ϮϬϟ΍ ΕΎϔϴϜϣ ΞϣΩ ϦϜϤϳ MAC-CWX/CRX ϊϣ
ϒϴϴϜΘϟ΍ϭ ΔϳϮϬΘϟ΍ϭ ΔΌϓΪΘϠϟ ϡΎψϧ ϦϳϮϜΘϟ ϚϟΫϭ Ρϭ΍ήϤϟ΍ Ϧϣ ΔϠμϔϨϣ ΓΪΣϭ
)HVAC (Ϡϟϭ ΕΎϨϴΑΎϜϠϟ ϑήϐϟ΍ Γ΍ϮϬϤϟ΍ ΔϟϮϤΤϤ)TVR( )ϰηΎϤΘϳ ΎϤΑ ϊϣ
Ϣϗέ ϪϴΟϮΘϟ΍
ήϴϳΎόϣEN 50381(.
ίΎϬΠΑ ή
͋
ΨΒϤϟ΍ ΓΪΣϭ ΪϳϭΰΗ ϦϜϤϳ ΔΣϭήϤϟ΍ Δϋήγ ϞϳΪΒΗ.
13
These latter will be mounted diametrically opposed on a
stainless steel panel completed with through fi xing holes
and suitable gasket, in order to maintain the IP65 degree of
protection. The evaporator module is oriented towards internal
environment in order to decrease relevent temperature; while
condenser module, oriented toward the outside, will dissipate
the heat.
The following electric components in 2GD execution (with
their own certifi cation) are main elements of MAC-CWX and
MAC-CRX air conditioners:
• Alternative Hermetic Compressor, our series MCE;
• Fans’ motors;
• Solenoid Valve of reversal device, our series MEV;
• Aluminium alloy Enclosure containing equipments relating to
the conditioner’s functional logic.There are also the following
non-electrical components (risks analysis carried out):
• Fans;
• Air/Refrigerant gas heat exchangers, fi nned battery type,
with copper tubing and aluminuim fi ns;
• Cooling circuit made of copper welded with precious alloy,
completed with: lamination capillary tube, mechanical
deidratation fi lter, brass valves, pressure and temperature
control devices.
The MAC-CWX/CRX series air conditioners can be
combined with a separated group of fans, in order to form a
HVAC system for cabinets and TVR (Transportable Ventilated
Rooms, according to EN 50381 standard). The evaporator
module can be provided with a commutation device for fan
speed.
Mac-Crx montaggio a soffi tto.
AC_CatHVAC_rv03@1-20#.indd 13AC_CatHVAC_rv03@1-20#.indd 13 12/05/14 14.2812/05/14 14.28
Seitenansicht 12