s The hob is equipped with an anti-overheating safety device that can
be activated if the hob is installed over an oven that is not sufficiently
ventilated. In the event that this occurs, the control panel will show E2,
ER21 or ER40. We recommend that you increase the ventilation of the
hob by creating an opening in the side of the cabinet (8 cm x 5 cm).
s Ensure that the top rail is removed prior to installation, and that
no unit cross member is blocking the air outlets.
s If the hob is to be located above a working drawer, we recommend that
the drawer is not used for storing soft items, for example dusters or
towels; this is to minimize the risk of the cooling system air intakes being
obstructed.
How to install the hob
Overall dimensions of the hob:
Width: 900 mm Depth: 350 mm
Worktop cut-out dimensions:
Width: 880 mm Depth: 330 mm
1. Make the required hole in the worktop. Before doing this, you must
check the instructions supplied with any cooker hood to ensure that you
will have the required clearance. The cut-out (Fig.7) shows a 60mm gap
from the wall to the cut-out edge. The distance from the hob, when
fitted, to the back wall is 50mm.
If a splashback/worktop upstand is to be fitted, take this into account when
cutting the hole. The minimum distance that the hob should be positioned
away from the rear wall or splashback is 50mm.
2. Fix the foam seal underneath the appliance by following the outline of
the worktop upon which the hob will rest. This ensures an airtight seal
with the worktop. Do not use silicone type sealant.
Fig.5
Fig.6
400mm
600mm
Fig.7
min 4mm
Above an oven
40
40
60
40
A
ventilation
space
510
930
490
900
65
900
50
350
330
880
Fitting the Hob
Unpacking the hob:
Take care not to lose or mishandle any parts.
Fitting position of the hob:
This appliance must be installed a minimum of 50mm from any back wall
and a minimum of 180mm away from any adjacent vertical surfaces, e.g.
a tall cupboard end panel. This may be reduced to 100mm if the adjacent
surface is resistant to fire (tiles or steel, for example). These dimensions are
shown in Fig.7.
Ventilation requirements:
This appliance must be installed to allow air to flow freely to the air intake
and from the air outlet. Failure to allow sufficient ventilation could cause
damage to the hob and constitutes incorrect installation, which is not
covered by the warranty.
If fitting a cooker hood above the hob:
If a cooker hood is to be installed above the hob, the height of the hood
above the hob must be at least 600mm (650mm is recommended) (Fig.6).
If the instructions supplied with the hood dictate that the hood must be
installed at a height greater than 600mm, then that height is the minimum
required.
Wall furniture requirements:
The minimum height of any cabinet immediately above the hob is 900mm.
The minimum height of any adjacent units (including light pelmets) is
400mm, unless they are manufactured from a material resistant to fire (steel,
for example)
Notes:
s Do not position this appliance above a refrigeration unit. The heat
generated may cause the refrigeration unit to fail.
s This appliance is designed to be installed into cabinet units capable
of withstanding temperatures of 65°C or greater above ambient
temperature.
s Never place perishable foods, cleaning products or flammable items in
the cupboard below the appliance.
s If an oven is to be installed below the hob, the thermal safety system on
the hob will not allow the hob to be used at the same time as a pyrolytic
programme on the oven.