27
fig. 16
650 mm
500 mm
200 mm
450 mm
ai r v en t
700-900mm
If Fitting A Cooker Hood Above The
Range Cooker:
If a cooker hood is to be installed above the range cooker, the height
of the hood above the burners must be at least 700mm (750mm is
recommended). If the instructions supplied with the hood dictate that
the hood must be installed at a height greater than 700mm, then that
height is the minimum required.
Wall furniture requirements:
The minimum height of any cabinet immediately above the hob is
900mm. The minimum height of any adjacent
units (including light pelmets) is 450mm, unless they are manufactured
from a material resistant to fire (steel, for example)
Notes:
Do not position this appliance
adjacent to a refrigeration unit. The
heat generated may cause the
refrigeration unit to fail.
This appliance is designed to be
installed adjacent to cabinet units
capable of withstanding temperatures
of 65°C or greater above ambient
temperature.