4-1
0 Operating Instructions
Example
1:
Cartoning
(One
End
Only)
(continued)
PiN
108
389A
57·28 1
/9
3
Converting Distance Measurements
to
Tlme Values
Each
of
the distances must be converted to time values.
1.
Measure the conveyor fine speed.
(l)
Metric: measure in meters per minute (m/min)
English: measure in feet per minute (ftlmin)
2. Use the appropriate formula to convert each measurement to a time value. (
2
)
Metric:
0
·
06
~
~is~nce
)mm)
- Time in seconds
me pee
English:
5 x Distance {in.) Ti . d
L.
5
d -
1me
m secon s
me
pee
3.
Calculate all the transition values for your pattern by adding
up
the delays
and durations. Write them on your pattern drawing.
<'>
For this example, the line speed is 45.7 m/min (150ft/min).
<
2
> In the gun 1 bead in this example, the first delay
(T1)
includes the gun to
trigger distance
of
150 mm plus the 1
00
mm distance from the substrate
edge to the start
of
the first duration. This cumulative distance {250 mm) was
then converted using the Metric formula:
0.
06x250mm
45
.
7
mfmin
0.328 seconds (328
ms
)
In the two lower bead sequences, the first delay (T1) includes the gun to trig-
ger distance
of
150 mm plus the 75 mm distance from the substrate edge to
the start
of
the first duration. This cumulative distance {225 mm) was then
converted using the Metric formula:
0.06x
225 mm
45
.
7
mfmln
-0.295
seconds (295 ms)