Dell PowerEdge R730 and R730xdOwner's ManualRegulatory Model: E31S SeriesRegulatory Type: E31S001

Seite 2 - Notes, Cautions, and Warnings

Front-panel features and indicatorsFigure 1. Front-panel features and indicators (3.5 inch hard-drive chassis)—PowerEdge R730Item Indicator, button, o

Seite 3 - Contents

Steps1. Unpack the expansion card and prepare it for installation.For instructions, see the documentation accompanying the card.2. Lift the expansion-

Seite 4

Figure 41. Removing and installing an expansion-card from expansion-card riser 11. tab A 2. expansion-card riser 1 cage3. expansion-card connector 4.

Seite 5

Steps1. Unpack the expansion card and prepare it for installation.For instructions, see the documentation accompanying the card.2. Press tab A and rot

Seite 6

Figure 42. Removing and installing the riser 1 blank1. slot on the chassis 2. tab (2)3. riser 1 blankInstalling the riser 1 blankTo install the riser

Seite 7

StepsHolding the slots on the expansion-card riser, lift the riser from the riser connector on the system board.NOTE: To remove expansion-card risers

Seite 8

Figure 44. Identifying connectors on the expansion card riser 11. expansion-card slot 1 2. expansion-card slot 23. expansion-card slot 3105

Seite 9 - About your system

Figure 45. Removing and installing the expansion card riser 21. power connector (for GPU cards) 2. expansion-card riser 23. riser guide-back 4. expans

Seite 10

Figure 46. Identifying connectors on the expansion card riser 21. expansion-card slot 4 2. expansion-card slot 53. power connector (for GPU cards)107

Seite 11

Figure 47. Removing and installing the expansion card riser 31. riser guide-front 2. power connector (for GPU cards)3. expansion-card riser 3 4. riser

Seite 12

Figure 48. Identifying connectors on the expansion card riser 3 (default)1. expansion-card slot 6 2. expansion-card slot 73. power connector (for GPU

Seite 13

Item Indicator, button, or connectorIcon DescriptionTo reset iDRAC (if not disabled in F2 iDRAC setup) press and hold the button for more than 15 seco

Seite 14

Installing expansion-card risersPrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before working inside

Seite 15

Removing a GPU cardPrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before working inside your system.C

Seite 16 - LCD panel features

Figure 50. Removing and installing the GPU card1. expansion-card locking tab (3) 2. GPU card3. PCIe card holder latch 4. expansion-card latch 5. expan

Seite 17 - Setup menu

Steps1. Unpack the GPU cards and the GPU enablement kit.2. Install the heat sinks from the kit and reinstall the cooling shroud.3. Close the expansion

Seite 18 - Diagnostic indicators

2. Follow the procedure listed in Before working inside your system.CAUTION: Many repairs may only be done by a certified service technician. You shou

Seite 19

Figure 51. Removing and installing the Internal Dual SD Module (IDSDM)1. Internal Dual SD module 2. LED status indicator (2)3. SD card (2) 4. SD card

Seite 20 - Hard-drive indicator codes

Convention IDSDM indicator code ConditionC Flashing amber Indicates card mismatch or that the card has failedD Amber Indicates that the card is offlin

Seite 21

Steps1. Using a #1 Phillips screwdriver, loosen the captive screws that secure the network daughter card to the system board.2. Hold the network daugh

Seite 22 - Quick Sync indicator codes

Installing the network daughter cardPrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before working ins

Seite 23

Steps1. Locate the USB connector or USB key on the system board.NOTE: To locate the internal USB connector on the system board, see System board conne

Seite 24

Figure 2. Front-panel features and indicators (2.5 inch hard-drive chassis)—PowerEdge R730Item Indicator, button, or connectorIcon Description1 Power-

Seite 25

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in

Seite 26 - Power indicator codes

Figure 55. Installing the system battery1. system battery 2. positive side of the battery connectorNext steps1. Install the cooling shroud.2. Follow t

Seite 27

Hot Spare featureYour system supports the Hot Spare feature that significantly reduces the power overhead associated with power supply redundancy.When

Seite 28

Figure 56. Removing and installing the power supply blank1. power supply blank 2. power supply bayInstalling the power supply unit blankInstall the po

Seite 29 - Documentation matrix

Figure 57. Removing and installing an AC power supply unit1. release latch 2. power supply unit cable connector3. power supply unit 4. connector5. pow

Seite 30 - Quick Resource Locator

3. Slide the new power supply unit into the chassis until the power supply unit is fully seated and the release latch snaps into place.NOTE: If you un

Seite 31 - Setting up your system

Required wires• One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC]• One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return)• One UL

Seite 32 - Remote management

Assembling the DC input power wiresPrerequisitesWARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all co

Seite 33

Removing a DC power supply unitPrerequisitesWARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connec

Seite 34 - Navigation keys

Installing a DC power supply unitPrerequisitesWARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all conn

Seite 35 - About System Setup

Item Indicator, button, or connectorIcon Description4 Video connector Allows you to connect a VGA display to the system.5 LCD menu buttons Allow you t

Seite 36

2. Follow the procedure listed in Before working inside your system.3. Remove the following:a. cooling shroudb. cooling-fan assemblyc. hard-drive tray

Seite 37

Figure 61. Removing and installing the system board1. release pin 2. system board3. system-board holderNext steps1. Replace the system board. See, Ins

Seite 38

2. Follow the procedure listed in Before working inside your system.CAUTION: Many repairs may only be done by a certified service technician. You shou

Seite 39 - SATA Settings screen details

b. If the service tag is not backed up in the backup flash device, enter the system service tag manually. For more information, see Entering the syste

Seite 40

CAUTION: Do not remove an installed Trusted Platform Module (TPM). Any attempt to remove an installed TPM from the system board may damage the TPM.Ste

Seite 41

5. Save the settings.6. Reboot your system.7. Enter System Setup again.8. In the System Setup Main Menu, click System BIOS → System Security Settings.

Seite 42 - Boot Settings screen details

Figure 63. Removing and installing a 2.5 inch hard-drive blank1. hard-drive blank 2. release buttonInstalling a 2.5 inch hard-drive blankPrerequisites

Seite 43

Figure 64. Removing and installing a 2.5 inch hard-drive blank (back)1. hard-drive blank (back)Installing a 2.5 inch hard-drive blank (back)Prerequisi

Seite 44

Figure 65. Removing and installing a 1.8 inch hard-drive blank1. hard-drive blank 2. release buttonNext stepsIf applicable, install the front bezel.In

Seite 45

StepsPress the release button and slide the blank out of the hard-drive slot.Figure 66. Removing and installing a 3.5 inch hard-drive blank1. hard-dri

Seite 46

Figure 3. Front-panel features and indicators (2.5 inch hard-drive chassis)—PowerEdge R730xdFigure 4. Front-panel features and indicators (3.5 inch ha

Seite 47

Figure 67. Removing and installing a 1.8 hard drive into a hard-drive carrier1. hard drive carrier 2. hard-drive Installing a 1.8 inch hard drive into

Seite 48

If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. When the hard-drive indicators are off, the hard d

Seite 49

Figure 69. Removing and installing a 1.8 inch hot-swap hard drive1. release button 2. hard-drive carrier3. hard-drive carrier handleRelated videohttp:

Seite 50 - Changing the boot order

CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the documentation supplied with your operat

Seite 51 - Choosing the system boot mode

Installing a hard drive into a hard-drive carrierPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should onl

Seite 52

Removing the hard-drive backplane (R730)Prerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before working

Seite 53 - Safety instructions

3. backplane power cable 4. release tab (2)5. SAS cable (2) 6. mini SAS connector (2)7. hard-drive connector (16)Figure 72. Cabling diagram—2.5 inch (

Seite 54 - Front bezel (optional)

Figure 73. Removing and installing the 2.5 inch (x8) SAS/SATA backplane—PowerEdge R7301. hard-drive connector (8) 2. hard-drive backplane3. release ta

Seite 55 - 1. bezel lock 2. front bezel

Figure 74. Cabling diagram—2.5 inch (x8) SAS/SATA backplane—PowerEdge R730 (option 1)1. hard-drive backplane 2. backplane signal connector 13. system

Seite 56 - Removing the system cover

Figure 75. Cabling diagram—2.5 inch (x8) SAS/SATA backplane—PowerEdge R730 (option 2)1. hard-drive backplane 2. backplane signal connector 13. system

Seite 57 - Installing the system cover

Item Indicator, Button, or ConnectorIcon Description1 Diagnostic indicators The diagnostic indicators light up to display error status.2 System identi

Seite 58 - Inside the system

Figure 76. Removing and installing the 3.5 inch (x8) SAS/SATA backplane—PowerEdge R7301. release tab (2) 2. SAS cable (2)3. backplane signal connector

Seite 59 - Cooling shroud

Figure 77. Cabling diagram—3.5 inch (x8) SAS/SATA backplane—PowerEdge R730 (option 1)1. hard-drive backplane 2. backplane signal connector 13. system

Seite 60 - Removing the cooling shroud

Figure 78. Cabling diagram—3.5 inch (x8) SAS/SATA backplane—PowerEdge R730 (option 2)1. hard-drive backplane 2. backplane signal connector 13. system

Seite 61 - Hard-drive tray assembly

4. Remove the cooling-fan assembly.5. Remove all hard drives.CAUTION: Many repairs may only be done by a certified service technician. You should only

Seite 62

Figure 79. Removing and installing the 2.5 inch (x24) SAS/SATA backplane—PowerEdge R730xd1. release tab (2) 2. left ear control panel cable3. backplan

Seite 63

Figure 80. Cabling diagram—2.5 Inch (x24) SAS/SATA backplane—PowerEdge R730xd (option 1)1. hard-drive backplane expander 2. backplane signal connector

Seite 64

Figure 81. Cabling diagram—2.5 Inch (x24) SAS/SATA backplane—PowerEdge R730xd (option 2)1. hard-drive backplane expander 2. hard-drive backplane3. bac

Seite 65

Figure 82. Cabling diagram—2.5 Inch (x24) SAS/SATA backplane—PowerEdge R730xd (option 3)1. hard-drive backplane expander 2. hard-drive backplane3. sys

Seite 66

Figure 83. Removing and installing the 3.5 inch (x12) SAS/SATA backplane—PowerEdge R730xd1. release tab (2) 2. SAS cable A23. SAS cable A1 4. left ear

Seite 67

Figure 84. Cabling diagram—3.5 inch (x12) SAS/SATA backplane—PowerEdge R730xd (option 1)1. hard-drive backplane 2. system board3. backplane signal con

Seite 68

Item Indicator, Button, or ConnectorIcon Description7 USB management port/iDRAC DirectAllows you to connect USB devices to the system or provides acce

Seite 69

Figure 85. Cabling diagram—3.5 inch (x12) SAS/SATA backplane—PowerEdge R730xd (option 2)1. hard-drive backplane 2. system board3. backplane signal con

Seite 70 - Cooling fans

Figure 86. Removing and installing the 1.8 Inch (x18) SAS/SATA backplane—PowerEdge R730xd1. release pin 2. left ear control panel cable3. SAS A2 cable

Seite 71 - Installing a cooling fan

Figure 87. Cabling diagram—1.8 Inch (x18) SAS/SATA backplane—PowerEdge R730xd1. hard-drive backplane expander 2. system board3. backplane signal conne

Seite 72 - Cooling-fan assembly

Installing the hard-drive backplane (R730 and R730xd)Prerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in B

Seite 73

Figure 88. Removing and installing the optional 2.5 inch (x2) hard-drive backplane—PowerEdge R730xd1. SAS cable 2. release pin3. hard-drive connector

Seite 74 - System memory

NOTE: This procedure applies only to PowerEdge R730xd systems.Steps1. Align the notches on the backplane with the notches on the chassis.2. Lift the r

Seite 75

Figure 89. Removing and installing the tape backup unit1. tape backup unit 2. tape backup unit slot3. release tabInstalling the tape backup unit Prere

Seite 76 - Mode-specific guidelines

Optical drive (optional)Removing the optical drivePrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Befo

Seite 77 - Memory mirroring

3. release tabNext stepsFollow the procedure listed in After working inside your system.Installing the optical drivePrerequisites1. Ensure that you re

Seite 78 - Sample memory configurations

Figure 91. Removing and installing the SD vFlash media card1. SD vFlash media card 2. SD vFlash media-card slot3. To install an SD vFlash media card,

Seite 79

Item Button Description1 Left Moves the cursor back in one-step increments.2 Select Selects the menu item highlighted by the cursor.3 Right Moves the

Seite 80 - Removing memory modules

Figure 92. Removing and installing the vFlash media unit1. cable 2. screw3. vFlash media unit 4. vFlash media slot5. standoffNext stepsFollow the proc

Seite 81

Steps1. Slide in and align the vFlash media unit with the vFlash media slot on the back of the chassis.2. Connect the cable to the vFlash media unit.3

Seite 82 - Installing memory modules

Figure 93. Removing and installing the control panel—3.5 inch hard drive system—PowerEdge R7301. control panel 2. control-panel board3. control-panel

Seite 83 - Processors

Figure 94. Removing and installing the control panel—2.5 inch hard-drive system—PowerEdge R7301. control panel 2. control-panel board3. control-panel

Seite 84 - Removing a processor

Figure 95. Removing and installing the information tag1. information tag 2. tab 3. slotNext steps1. Replace the control panel. See Installing the cont

Seite 85

Removing the control panel (R730xd)Prerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before working insi

Seite 86 - Figure 33. Processor shield

Figure 96. Removing and installing the control panel—PowerEdge R730xd1. screw (3) 2. control panel3. hard-drive backplane 4. connector5. plastic pull

Seite 87

Steps1. Fold the PPID label around the cable.2. Fold the pull tab close to the connector and guide the connector and pull tab into the channel.3. Push

Seite 88 - Installing a processor

Figure 97. Removing and installing the I/O panel —PowerEdge R730xd1. I/O panel cable 2. hard-drive backplane3. screw (3) 4. I/O panel5. chassisNext st

Seite 89

Steps1. Fold the PPID label around the cable.2. Push the cable until the cable passes completely through the channel.CAUTION: To prevent damage to the

Seite 90 - PCIe card holder

View menuNOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next action.Option DescriptioniDRAC IP

Seite 91

5Troubleshooting your systemSafety first—for you and your systemCAUTION: Many repairs may only be done by a certified service technician. You should o

Seite 92

3. If the problem is resolved, restart the system, enter the System Setup, and check if the non-functioning USB ports are enabled.Check if USB 3.0 is

Seite 93 - Cable retention bracket

Troubleshooting iDRAC Direct (laptop connection)For information on USB laptop connection and server configuration, see the Integrated Dell Remote Acce

Seite 94

7. Ensure that all network cables are of the proper type and do not exceed the maximum length.Next stepsIf all troubleshooting fails, see Getting Help

Seite 95

Troubleshooting a damaged systemPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform trouble

Seite 96

Steps1. Re-enter the time and date in the System Setup.2. Turn off the system and disconnect it from the electrical outlet for at least one hour.3. Re

Seite 97

Troubleshooting cooling problemsCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

Seite 98

3. If the fan functions properly, install the system cover.Next stepsIf the problem persists, see Getting Help.Troubleshooting system memoryPrerequisi

Seite 99

Next stepsIf the problem persists after all memory modules have been checked, see Getting Help.Troubleshooting an internal USB keyPrerequisitesCAUTION

Seite 100

5. Install the system cover.6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.7. Enter the S

Seite 101

Icon Description Condition Corrective actionelectrical error (for example, voltage out of range, or a failed power supply or voltage regulator).a prob

Seite 102 - Removing the riser 1 blank

Steps1. Use a different tape cartridge.2. Ensure that the device drivers for the tape backup unit are installed and are configured correctly. See your

Seite 103 - Installing the riser 1 blank

Troubleshooting a storage controllerCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting

Seite 104

Steps1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.2. Turn off the system and attached peripherals, and d

Seite 105 - 3. expansion-card slot 3

System messagesFor a list of event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event a

Seite 106 - 5. riser guide-front

6Using system diagnosticsIf you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The

Seite 107

System diagnostic controlsMenu DescriptionConfiguration Displays the configuration and status information of all detected devices.Results Displays the

Seite 108

7Jumpers and connectorsSystem board jumper settingsFor information on resetting the password jumper to disable a password, see Disabling a forgotten p

Seite 109

System board connectorsFigure 98. System board jumpers and connectorsItem Connector Description1 J_BP_SIG1 Backplane signal connector 12 J_PS_2 PSU 2

Seite 110

Item Connector Description11 J_USB USB connector12 J_VIDEO_REAR Video connector13 J_COM1 Serial connector14 J_IDRAC_RJ45 iDRAC8 connector15 J_CYC Syst

Seite 111 - Removing a GPU card

Item Connector Description44 J_FAN2U_1 Cooling fan connector45 J_CTRL_PNL Control panel signal connector46 CPU 1 Processor 147 J_FP_USB Front-panel US

Seite 112 - Installing a GPU card

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Seite 113 - Removing an internal SD card

Hard-drive indicator codesFigure 7. Hard-drive indicators1. hard-drive activity indicator 2. hard-drive status indicator 3. hard driveFigure 8. Hard-

Seite 114

8Technical specificationsProcessorProcessor type One or two Intel Xeon processor E5-2600 v3 product familyPowerAC power supply (per power supply)Watta

Seite 115

Expansion BusNOTE: To use slots 1 through 4, both the processors must be installed.(Slot 5) One full-height, full-length x8 linkRiser 3 (default) (Slo

Seite 116 - Network daughter card

DrivesSSD, or Nearline SAS drives in hard-drive slots 0 through 11 and 12 through 13.orTwelve plus two and four–hard-drive systemsUp to twelve 3.5 inc

Seite 117

ConnectorsNOTE: The card slot is available for use only if the iDRAC8 Enterprise license is installed on your system.FrontUSB One 4-pin, USB 2.0-compl

Seite 118

PhysicalEmpty weightR730• 18.9 kg (41.67 lb) (3.5 inch hard drive systems)• 20.8 kg (45.86 lb) (2.5 inch hard drive systems)R730xd• 19 kg (41.89 lb) (

Seite 119 - System battery

Environmental specificationsMaximum altitudeOperating3048 m (10,000 ft).Storage 12,000 m (39,370 ft).Operating temperature de-ratingUp to 35 °C (95 °F

Seite 120

Expanded operating temperatureNOTE: When operating in the expanded temperature range, system performance may be impacted.NOTE: When operating in the e

Seite 121 - Power supply units

9Getting helpContacting DellAbout this taskNOTE: Dell provides several online and telephone-based support and service options. If you do not have an a

Seite 122 - Hot Spare feature

specific Quick Resource (QR) code located on your Dell PowerEdge system. To try out the QR code, scan the following image.208

Seite 123

Drive-status indicator pattern (RAID only) ConditionBlinks green two times per second Identifying drive or preparing for removal.Off Drive ready for i

Seite 124

Convention iDRAC Direct LED indicator patternConditionC Green and turns offIndicates that the file transfer is complete.D Not lit Indicates that the U

Seite 125 - Required tools

Power indicator pattern ConditionSlow blink Quick Sync is waiting to be configured from iDRAC.Solid Quick Sync is ready to transfer.Blinks three times

Seite 126 - Required wires

Figure 12. Back-panel features and indicators—PowerEdge R730xdItem Indicator, button, or connectorIcon Description1 System identification buttonThe id

Seite 127

Item Indicator, button, or connectorIcon Description5 Serial connector Allows you to connect a serial device to the system.6 Video connector Allows yo

Seite 128

NIC indicator codesFigure 13. NIC indicators1. link indicator 2. activity indicatorIndicator Indicator codeLink and activity indicators are off The NI

Seite 129 - System board

Figure 14. AC power supply unit status indicator1. AC power supply unit status indicator/handleConvention Power indicator patternConditionA Green The

Seite 130

Convention Power indicator patternConditionCAUTION: When correcting a power supply unit mismatch, replace only the power supply unit with the flashing

Seite 131 - Installing the system board

Convention Power indicator patternConditionA Green The handle/LED indicator lights green indicating that a valid power source is connected to the powe

Seite 132

Contents1 About your system... 9Supported configurations.

Seite 133 - Trusted Platform Module

To... Refer to...Get an overview of the Dell Systems Management offeringsDell OpenManage Systems Management Overview Guide at dell.com/openmanagemanua

Seite 134 - Figure 62. Installing the TPM

2Performing initial system configuration After you receive your PowerEdge system, you must set up your system, install the operating system, and set u

Seite 135 - Hard drives

Information about logging in to iDRACYou can log in to iDRAC as an iDRAC local user, as a Microsoft Active Directory user, or as a Lightweight Directo

Seite 136

NOTE: If you do not have the service tag, select Automatically detect my Service Tag for me to allow the system to automatically detect your service t

Seite 137

3Pre-operating system management applicationsThe pre-operating system management applications for your PowerEdge system help you manage different sett

Seite 138

About System SetupUsing System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your system.You can access System Se

Seite 139

Menu Item DescriptionProcessor Settings Displays information and options related to the processor such as speed, cache size, and so on.SATA Settings D

Seite 140

Menu Item DescriptionContact InformationSystem CPLD VersionDisplays the current revision of the system CPLD firmware.UEFI Compliance VersionDisplays t

Seite 141

Menu Item Descriptioninstalled. If Disabled, the system supports NUMA (asymmetric) memory configurations. By default, Node Interleaving option is set

Seite 142

Menu Item DescriptionLogical Processor IdlingEnables or disables the operating system capability to put logical processors in the idling state in orde

Seite 143

Serial Communication screen details...45System Profile Setting

Seite 144 - Hard-drive backplane

ExampleMenu Item DescriptionEmbedded SATA Enables the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the Embedded SATA option i

Seite 145

Menu Item DescriptionDrive Type Displays the type of drive attached to the SATA port.Capacity Displays the total capacity of the hard drive. The field

Seite 146

Menu Item DescriptionPort I Sets the drive type of the selected device. For Embedded SATA settings in ATA mode, set this field to Auto to enable BIOS

Seite 147 - 7. mini SAS connector (2)

Menu Item Descriptionlist is attempted to boot. When set to Enabled, all hard disk devices are attempted in order, as listed in the Hard-Disk Drive Se

Seite 148

Menu Item DescriptionIntegrated RAID ControllerEnables or disables the integrated RAID controller. By default, the option is set to Enabled.Integrated

Seite 149

Serial Communication screen detailsYou can use the Serial Communication screen to view the properties of the serial communication port.You can view th

Seite 150 - 7. hard-drive connector (8)

ExampleMenu Item DescriptionSystem Profile Sets the system profile. If you set the System Profile option to a mode other than Custom, the BIOS automat

Seite 151

Menu Item DescriptionNumber of Turbo Boot Enabled Cores for Processor 1NOTE: If there are two processors installed in the system, you see an entry for

Seite 152

Menu Item DescriptionClears all the contents of the TPM. By default, the TPM Clear option is set to No.Intel TXT Enables or disables the Intel Trusted

Seite 153

Menu Item DescriptionAuthorized Signature DatabaseImports, exports, deletes, or restores entries in the Authorized Signature Database (db).Forbidden S

Seite 154

Installing the cooling-fan assembly...74System memory...

Seite 155

Menu Item Descriptionresults can be applied. It takes the system longer to be ready due to the forced system reset. When disabled, ISC does not execut

Seite 156 - 7. SAS B1 connector

Choosing the system boot modeSystem Setup enables you to specify the boot mode for installing your operating system:• BIOS boot mode (the default) is

Seite 157

6. Re-enter the system password, and click OK.7. Select Setup Password, enter your system password and press <Enter> or <Tab>.A message pr

Seite 158

4Installing and removing system componentsSafety instructionsWARNING: Whenever you need to lift the system, get others to assist you. To avoid injury,

Seite 159

Recommended toolsYou need the following tools to perform the removal and installation procedures:• Key to the bezel lock. This is only required when y

Seite 160

Figure 16. Removing and installing the front bezel1. bezel lock 2. front bezelFigure 17. Removing and installing the Quick Sync bezel1. keylock 2. Qui

Seite 161

Related videoshttp://www.Dell.com/QRL/Server/PER730/Bezelhttp://www.Dell.com/QRL/Server/PER730/iDRAC-QuickSyncInstalling the front bezel1. Hook the ri

Seite 162

Figure 18. Removing and installing the system cover1. system cover 2. latch3. latch release lockRelated videohttp://www.Dell.com/QRL/Server/PER730/Cov

Seite 163

3. Turn the latch release lock clockwise to the locked position.4. Install the optional bezel.5. Reconnect the system to its electrical outlet and tur

Seite 164

7. expansion-card riser 3 8. network daughter card9. expansion-card riser 2 10. expansion-card riser 111. hard-drive backplaneFigure 20. Inside the sy

Seite 165 - Tape backup unit (optional)

Replacing the internal USB key... 118System battery...

Seite 166

Removing the cooling shroudPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshoot

Seite 167 - Optical drive (optional)

Installing the cooling shroudPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform troublesho

Seite 168 - SD vFlash media card

Figure 22. Removing and installing the hard-drive tray1. hard-drive tray handle (2) 2. hard drive (4)3. hard-drive indicator 4. SAS cable5. backplane

Seite 169

Steps1. Lift the hard-drive tray handles 90 degrees.2. Hold the hard-drive tray handles and align the slots on the hard-drive tray with the guide pins

Seite 170

Figure 23. Removing and installing the hard-drive blank from a hard-drive carrier1. hard-drive blank 2. tab on the hard-drive carrier (4)3. hard-drive

Seite 171 - Control panel assembly

Removing a hard-drive carrier from the hard-drive trayPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You shoul

Seite 172

Figure 24. Removing and installing a hard-drive carrier from the hard-drive tray1. release tab on the hard-drive tray 2. hard-drive carrier handle3. h

Seite 173

Steps1. Lift the hard-drive tray handles.2. If a hard-drive blank is installed in the hard-drive slot, remove it.3. Insert the hard-drive carrier into

Seite 174

3. hard-drive carrierNext stepsFollow the procedure listed in After working inside your system.Installing a hard drive into a hard-drive carrierPrereq

Seite 175

Figure 26. Removing and installing the 3.5 inch (x4) hard-drive backplane—PowerEdge R730xd1. release tab (2) 2. hard-drive indicators3. hard-drive con

Seite 176

Installing the tape backup unit ...166Optical drive (o

Seite 177

Cooling fansYour system supports six hot-swappable cooling fans.NOTE: In the event of a problem with a particular fan, the fan number is referenced by

Seite 178

Figure 27. Removing and installing a cooling fan1. cooling-fan assembly 2. cooling-fan connector (6)3. fan release tab (6) 4. cooling fan (6)5. coolin

Seite 179

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in

Seite 180 - Troubleshooting your system

Figure 28. Removing and installing the cooling-fan assembly1. cooling-fan assembly 2. cooling fan (6)3. release lever (2) 4. guide pin on the system b

Seite 181

Installing the cooling-fan assemblyPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform trou

Seite 182 - Troubleshooting a NIC

Figure 29. Memory socket locationsMemory channels are organized as follows:Processor 1 channel 0: slots A1, A5, and A9channel 1: slots A2, A6, and A10

Seite 183 - Troubleshooting a wet system

channel 3: slots B4, B8, and B12The following table shows the memory populations and operating frequencies for the supported configurations.DIMM Type

Seite 184

NOTE: You can mix x4 and x8 DRAM based DIMMs to support RAS features. However, all guidelines for specific RAS features must be followed. x4 DRAM base

Seite 185 - Power supply unit problems

Sample memory configurationsThe following tables show sample memory configurations for one and two processor configurations that follow the appropriat

Seite 186 - Troubleshooting cooling fans

System capacity (in GB)DIMM size (in GB)Number of DIMMsDIMM rank, organization, and frequencyDIMM slot population2R, x4 and 2R, x8, 1600 MT/sNOTE: 16

Seite 187 - Troubleshooting system memory

Troubleshooting processors...192System messa

Seite 188 - Troubleshooting an SD card

System capacity (in GB)DIMM size (in GB)Number of DIMMsDIMM rank, organization, and frequencyDIMM slot population160 8 202R, x8, 1866 MT/s2R, x8, 1600

Seite 189

1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before working inside your system.3. Remove the cooling shroud.4. I

Seite 190 - Troubleshooting a hard drive

Installing memory modulesPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshootin

Seite 191

Figure 31. Installing the memory module1. memory module 2. alignment key3. memory-module socket ejector (2) When the memory module is properly seated

Seite 192 - Troubleshooting processors

Removing a processorPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and

Seite 193 - System messages

Figure 32. Removing and installing a processor heat sink1. captive screw (4) 2. heat sink3. processor socket 4. slot (4)CAUTION: The processor is held

Seite 194 - Using system diagnostics

Figure 33. Processor shield1. close first socket release lever 2. lock icon3. processor 4. open first socket release lever5. unlock icon2. To remove t

Seite 195 - System diagnostic controls

Figure 34. Removing and installing a processor1. close first socket-release lever 2. pin-1 indicator of processor3. processor 4. slot (4)5. processor

Seite 196 - Jumpers and connectors

Installing a processorPrerequisitesCAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting a

Seite 197 - System board connectors

CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages easily into the socket.b. Align the pin-1 indi

Seite 198

1About your systemThe Dell PowerEdge R730 and R730xd systems are rack servers that support up to two Intel Xeon E5-2600 v3 processors, up to 24 DIMMs,

Seite 199

3. thermal-grease syringeNOTE: The thermal-grease is intended for one-time use only. Dispose of the syringe after you use it.c. Place the heat sink on

Seite 200 - Technical specifications

Figure 36. Removing and installing the PCIe card holder1. PCIe card holder 2. release tabNext steps1. Replace the PCIe card holder. See Installing the

Seite 201

Opening and closing the PCIe card holder latchPrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Before w

Seite 202

Cable retention bracketRemoving the cable retention bracketPrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure liste

Seite 203

Next steps1. Replace the cable retention bracket. See Installing the cable retention bracket. 2. Follow the procedure listed in After working inside y

Seite 204

Steps1. Loosen the screws that secure the integrated storage controller cable to the integrated storage-controller card connector on the system board.

Seite 205

Installing the integrated storage controller cardPrerequisites1. Ensure that you read the Safety instructions. 2. Follow the procedure listed in Befor

Seite 206

Riser PCIe slot Processor connectionHeight Length Link width Slot width1 3 Processor 2 Low Profile Half Length x8 x162 4 Processor 2 Full Height Full

Seite 207 - Getting help

Card priorityCard type Slot priority Max allowedPowerEdge R730PowerEdge R730xdPowerEdge R730PowerEdge R730xd12 Gb SAS (full height) 7, 6, 4, 5 6, 4, 5

Seite 208

Figure 40. Removing and installing an expansion card from expansion-card riser 2 or 31. expansion card 2. expansion-card latch3. expansion-card riser