C
Flame failure
probe “T
Ignitor S
Correct Positioning of the Auxiliary, Semi-rapid and Rapid Burners
It is very important to check that the burner ame spreader F and the cap C have been correctly
positioned (see gs. 8 and 9). They shall be level and must not rotate. Failure to do so can cause serious
problems.
The pan supports shall be correctly positioned as indica-
ted in g. 10. The pan supports shall be level and must not
rotate.
Be sure not to t the triple-ring burner pan support on the
auxiliary, semirapid or rapid burners. The triple-ring burner
pan support IS ONLY to be used on the triple-ring burner.
Fig. 9