Correct Positioning of the Triple Ring Burner
The triple ring burner must be correctly positio-
ned (see g. 11); the burner ribs must be tted in
their housing as shown by the arrow. The burner
correctly positioned must not rotate (g. 12).
Then position the cap A and the ring B (gs. 12
and 13). They shall be level.
The pan support shall be correctly positioned as
indicated in g. 14. The pan support shall be level
and must not rotate.
Be sure not to t the auxiliary, semirapid or rapid
burner pan support on the triple-ring burner. The
auxiliary, semirapid or rapid burner pan support
IS ONLY to be used on the auxiliary, semirapid or
rapid burners.
A
B
Flame
failure
probe “T
Ignitor S
Fig. 14
Fig. 13
Fig. 12
Fig. 11